Verified against three real sources on hardware, plus a 52-check regression suite that runs on the device from synthetic spectra. Identification - Model the spectral features that are not gamma lines: backscatter, Compton edge, single and double escape peaks, sum peaks, and 511 keV annihilation. The matcher assumed every peak was a line and handed these to whichever nuclide sat nearest, which was the single cause behind phantom Na-22, Ba-133 and Am-241 rather than three separate faults. - A nuclide identified entirely below 110 keV must clear 9 sigma: that region is unmodelled X-ray fluorescence and backscatter, and a 4.9 sigma bump at 63 keV (really Th-234) was being reported as Am-241 at 100%. - Decay chains: two members with one line each corroborate one another, and a single member matched at 8 sigma can carry its chain. Requiring one nuclide to show two lines lost a thorium mantle whose Pb-212 was unmistakable. - Name the dominant chain rather than reporting a mixture. At this resolution both natural chains fit the same peaks - their line ratios differ by 0.4%, far below what 8.4% FWHM resolves - so real ore read 97% uranium against 70% thorium and was being called NATURAL MIX. - Chain anchors and verdicts now have hysteresis, so evidence sitting near a threshold no longer empties the candidate list or retracts a correct answer. Honesty of the display - An elevated sample is never called background. Identifying which nuclide takes counting time; noticing that something is there does not. - Verdicts are graded: URANIUM? below 80% confidence, with the number shown. - Quality grades the identification, not the strongest peak, so an unidentified bump no longer reports EXCELLENT. - Natural chains and K-40 must be above ambient to earn a verdict; every wall contains both. Regression suite (ANALYSIS_SELFTEST=1) Synthetic spectra built from the library at the detector's real resolution, with a Compton continuum and reproducible noise: uranium, thorium, mixed, Cs-137, Co-60, Am-241, K-40, background, indoor background with annihilation, ambient thorium in building materials, elevated-but-unidentified, insufficient data, and centroid accuracy. It fails on real defects - it caught a background false positive never seen on hardware, and rejected two fixes that broke other cases.
9 lines
379 B
Plaintext
9 lines
379 B
Plaintext
# Firmware update manifest for the RadiaCode Spectrometer Display.
|
|
#
|
|
# Fetched over a plain raw-file URL rather than the Gitea API, because API
|
|
# paths are commonly blocked by proxies while ordinary repo paths pass.
|
|
# Bump both lines when publishing a release.
|
|
|
|
version=1.0.6
|
|
url=https://git.vhelectronics.com/highway/RadiaCode-Spectrometer/releases/download/v1.0.6/firmware.bin
|